MR Series
Micro power packs for space demanding applications, 3 cavities for single and double acting circuits
Circuit schematic
- MR-A: MR version with two cavities, for double and single acting circuits with fix speed lowering control.
- MR-C: MR version with four cavities for double and single acting circuits, with fix and adjustable speed lowering control.
- MR-E: MR version with two cavities for double acting circuits with 4/2 and 4/3 solenoid valve control.
Double click on the image to zoom Drag to rotate
MR Series
Micro power packs for space demanding applications, 3 cavities for single and double acting circuits
Circuit schematic
- MR-A: MR version with two cavities, for double and single acting circuits with fix speed lowering control.
- MR-C: MR version with four cavities for double and single acting circuits, with fix and adjustable speed lowering control.
- MR-E: MR version with two cavities for double acting circuits with 4/2 and 4/3 solenoid valve control.
Group | Displacement [cm³/rev] | Flow [l/min] | Working pressure [bar] | Peak pressure [bar] |
---|---|---|---|---|
0,5 | 0,25 | 1,75 | 230 | 270 |
0,5 | 0,45 | 3,15 | 230 | 270 |
0,5 | 0,56 | 3,64 | 230 | 270 |
0,5 | 0,75 | 4,87 | 230 | 270 |
0,5 | 0,92 | 5,52 | 230 | 270 |
0,5 | 1,25 | 7,5 | 230 | 270 |
Volume [l] | Material |
---|---|
1 - 2 - 3 - 5 - 6 - 8 | Steel |
0,5 - 1 - 2 | Plastic |
Phases / Poles | Frame [mm] | Power [kW] | Voltage |
---|---|---|---|
Single phase / 2 | Ø71 | 0,37 - 0,55 | 230 VAC 50 Hz |
Single phase / 2 | Ø80 | 0,75 - 1,10 | 230 VAC 50 Hz |
Single phase / 4 | Ø71 | 0,25 - 0,37 | 230 VAC 50 Hz |
Single phase / 4 | Ø80 | 0,55 - 0,75 | 230 VAC 50 Hz |
Three phases / 2 | Ø63 | 0,18 - 0,25 | 230/400 VAC 50 Hz |
Three phases / 2 | Ø71 | 0,37 - 0,55 | 230/400 VAC 50 Hz |
Three phases / 2 | Ø80 | 0,75 - 1,10 | 230/400 VAC 50 Hz |
Three phases / 4 | Ø63 | 0,12 - 0,18 | 230/400 VAC 50 Hz |
Three phases / 4 | Ø71 | 0,25 - 0,37 | 230/400 VAC 50 Hz |
Three phases / 4 | Ø80 | 0,55 - 0,75 | 230/400 VAC 50 Hz |
Voltage [V] | Frame [mm] | Power [kW] |
---|---|---|
12 | Ø80 | 0,35 |
12 | Ø80 | 0,7 |
24 | Ø80 | 0,4 |
24 | Ø80 | 0,8 |
Valves |
---|
Solenoid cartridge valve 2/2 NO/NC, ON/OFF or proportional |
Manual cartridge lowering valve, ON/OFF or proportional |
Fixed compensated flow control valves |
Modular stackable CETOP 3 blocks and customized circuits |
Tech Data
Download PDF Tech Data TablesMW Series
Micro powerpacks for double acting circuits with reversible pump
Circuit schematic
- MW: basic MW circuit
- MW-1: same as MW plus exceeding flow discharge
- MW-2: same as MW-1 plus manual emerency override
Double click on the image to zoom Drag to rotate
MW Series
Micro powerpacks for double acting circuits with reversible pump
Circuit schematic
- MW: basic MW circuit
- MW-1: same as MW plus exceeding flow discharge
- MW-2: same as MW-1 plus manual emerency override
Group | Displacement [cm³/rev] | Flow [l/min] | Working pressure [bar] | Peak pressure [bar] |
---|---|---|---|---|
0,5 | 0,25 | 1,75 | 230 | 270 |
0,5 | 0,45 | 3,15 | 230 | 270 |
0,5 | 0,56 | 3,64 | 230 | 270 |
0,5 | 0,75 | 4,87 | 230 | 270 |
0,5 | 0,92 | 5,52 | 230 | 270 |
0,5 | 1,25 | 7,5 | 230 | 270 |
Volume [l] | Material |
---|---|
0,5 - 1 - 2 | Nylon |
1 | Nylon (glass reinforced) |
Phases / Poles | Frame [mm] | Power [kW] | Voltage |
---|---|---|---|
Single phase / 2 | Ø71 | 0,37 - 0,55 | 230 VAC 50 Hz |
Single phase / 2 | Ø80 | 0,75 - 1,10 | 230 VAC 50 Hz |
Single phase / 4 | Ø71 | 0,25 - 0,37 | 230 VAC 50 Hz |
Single phase / 4 | Ø80 | 0,55 - 0,75 | 230 VAC 50 Hz |
Three phases / 2 | Ø63 | 0,18 - 0,25 | 230/400 VAC 50 Hz |
Three phases / 2 | Ø71 | 0,37 - 0,55 | 230/400 VAC 50 Hz |
Three phases / 2 | Ø80 | 0,75 - 1,10 | 230/400 VAC 50 Hz |
Three phases / 4 | Ø63 | 0,12 - 0,18 | 230/400 VAC 50 Hz |
Three phases / 4 | Ø71 | 0,25 - 0,37 | 230/400 VAC 50 Hz |
Three phases / 4 | Ø80 | 0,55 - 0,75 | 230/400 VAC 50 Hz |
Voltage [V] | Frame [mm] | Power [kW] |
---|---|---|
12 | Ø80 | 0,7 |
24 | Ø80 | 0,8 |
12 | Ø80 | 0,35 |
24 | Ø80 | 0,4 |
Valves |
---|
Pressure relief valves and pilot operated check valves |
Manual override |
Cylinder differential volume drain valve |